Platform lift requirements: the regulations and standards in their own words
No single rulebook covers platform lifts. For buildings other than homes, the government’s guidance on access is Approved Document M volume 2; homes have volume 1. A business also has the Equality Act’s duty to make reasonable adjustments, and the Lifting Operations and Lifting Equipment Regulations 1998 (LOLER) and the Provision and Use of Work Equipment Regulations 1998 (PUWER) where the lift is used at work. The lift itself is built to a British Standard. This page sets out each from its own official page. It is not legal advice.
Last reviewed against its sources: 13 November 2026. Each figure links to the page it was read on.
Which source bears on which building
| Source | What it is about | Home | Business | Read |
|---|---|---|---|---|
| Approved Document M, volume 2 | Access to and use of buildings other than dwellings, including lifting devices | No | Yes | (Approved Document M, checked 13 November 2026) |
| Approved Document M, volume 1 | Dwellings, including lifts in homes built to be wheelchair accessible | New homes | No | (Approved Document M, checked 13 November 2026) |
| Equality Act 2010, sections 20 and 29, Schedule 2 | The duty on service providers to make reasonable adjustments | No | Yes | (legislation.gov.uk, checked 13 November 2026) |
| LOLER 1998 | Lifting equipment used at work: who has duties, and thorough examinations | See below | Where used at work | (legislation.gov.uk, checked 13 November 2026) |
| PUWER 1998 | Work equipment kept maintained and in good repair | No | Where used at work | (legislation.gov.uk, checked 13 November 2026) |
| BS 6440, BS EN 81-41, BS EN 81-40 | Product standards a lift is built to | Yes | Yes | (BSI, checked 13 November 2026) |
“Home” and “Business” are this site’s summary of whom each source is written for, not a legal opinion about your building.
Approved Document M: which versions are current
GOV.UK’s page for Approved Document M, last updated on 1 October 2024, carries volume 2 updated to incorporate the 2024 amendments, and says volume 1’s categories 2 and 3 for dwellings apply only where planning permission requires them (Approved Document M, checked 13 November 2026). An approved document is guidance on meeting the building regulations; building control, not a supplier, decides what a particular project needs.
For businesses Volume 2: lifting devices outside the home
Volume 2 opens its lifting section by asking that the device chosen be fit for purpose, and names the relevant legislation: the Lift Regulations 1997, LOLER 1998, PUWER 1998 and the Management of Health and Safety at Work Regulations 1999. It says lifting platforms should conform to the Supply of Machinery (Safety) Regulations 1992, which may be met through the relevant British Standards, the EN 81 series or, where necessary, certification by a Notified Body (Approved Document M, checked 13 November 2026).
On the lifts themselves, its main points are these, each paraphrased with its paragraph:
- Paragraphs 3.21 and 3.22. A passenger lift is the most suitable way between storeys; a lifting platform may be considered where one cannot be accommodated, chiefly in existing buildings (Approved Document M, checked 13 November 2026).
- Paragraphs 3.35 to 3.39. Lifting platforms are for wheelchair users, people with impaired mobility and their companions; they are slow and work by continuous pressure controls, and the designed duty cycle needs attention where use cannot be managed (Approved Document M, checked 13 November 2026).
- Paragraph 3.43. Travel of not more than 2m without a liftway enclosure, a rated speed no higher than 0.15m/s (Approved Document M, checked 13 November 2026), and minimum clear platforms from 800mm wide and 1250mm deep upwards (Approved Document M, checked 13 November 2026).
- Paragraphs 3.23 and 3.44 to 3.48. A wheelchair platform stairlift only in exceptional circumstances in an existing building, under supervision (Approved Document M, checked 13 November 2026).
- Paragraph 1.26. Ramps within set gradients, and another way in for wheelchair users, such as a lift, where the total rise is greater than 2m (Approved Document M, checked 13 November 2026).
How those points play out for a shop or office, with the figures in full, is on platform lifts for shops and businesses.
For homes Volume 1: dwellings
Volume 1 deals with lifts between floors. Where a dwelling is defined as wheelchair accessible, it says a suitable through-floor lift or lifting platform should be installed and commissioned, with a continuous liftway at least 1100mm wide and 1650mm long linking every floor and a power socket close by; it notes that a lifting platform to BS EN 81-41 may need a larger liftway and a three-phase supply (Approved Document M, checked 13 November 2026). It does not mention step lifts at an entrance. For a lift fitted inside an existing house, the Planning Portal’s guide says no planning permission is needed for an internal platform lift, but that it must comply with the building regulations on accessibility, fire safety, structural stability and electrical safety (Planning Portal, checked 13 November 2026).
Planning permission is a separate question
GOV.UK says building regulations approval is different from planning permission, that you might need both, that approval or special rules can apply to work not on its list, and that you should check with a building control body if you cannot decide whether you need approval (GOV.UK, checked 13 November 2026). Its list does not name lift installation, which is a reason to ask rather than assume. Outdoor lifts and permission are covered on outdoor step lifts.
The product standards
Platform lifts are built to their own standards, separate from those for passenger lifts. This is how BSI’s own catalogue lists them:
| Standard | Status | What it covers | Read |
|---|---|---|---|
| BS 6440:2011 | Current | Powered vertical lifting platforms with non-enclosed or partially enclosed liftways, travelling between two predefined levels | (BSI, checked 13 November 2026) |
| BS EN 81-41:2024 | Current | Vertical lifting platforms with enclosed liftways and a rated speed not greater than 0,15 m/s | (BSI, checked 13 November 2026) |
| BS EN 81-41:2010 | Withdrawn 9 Dec 2024 | The earlier edition for vertical lifting platforms | (BSI, checked 13 November 2026) |
| BS EN 81-40:2020 | Current, under review | Stairlifts and inclined lifting platforms, including wheelchair platforms moving in an inclined plane | (BSI, checked 13 November 2026) |
A buyer does not check a standard; a supplier should be able to say which one its model is built to and show the declaration of conformity.
For businesses The Equality Act
Three provisions matter for a business with steps. Section 20 sets the requirement to take reasonable steps where a physical feature puts a disabled person at a substantial disadvantage, with removing, altering or providing a means of avoiding the feature among the ways of doing so (legislation.gov.uk, checked 13 November 2026). Section 29 applies the duty to service providers (legislation.gov.uk, checked 13 November 2026). Schedule 2 says, for services, that the duty is owed to disabled people generally, allows a reasonable alternative method of providing the service, and requires no step that would fundamentally alter its nature (legislation.gov.uk, checked 13 November 2026). All three apply in England, Wales and Scotland. The Equality and Human Rights Commission’s code of practice could not be read for this site.
For businesses LOLER and PUWER, for lifts used at work
| Regulation | What it says | Read |
|---|---|---|
| LOLER, regulation 2 | Lifting equipment means work equipment for lifting or lowering loads, with its attachments. | (legislation.gov.uk, checked 13 November 2026) |
| LOLER, regulation 3 | Duties fall on employers for equipment their employees use at work, on relevant self-employed people, and on people who control lifting equipment for a trade, business or other undertaking, profit-making or not; it applies in Great Britain. | (legislation.gov.uk, checked 13 November 2026) |
| LOLER, regulation 9 | A thorough examination after installation and before first use where safety depends on the installation; then, for lifting persons where conditions cause deterioration, at least every 6 months, or under an examination scheme. | (legislation.gov.uk, checked 13 November 2026) |
| PUWER, regulation 5 | Work equipment maintained in an efficient state, in efficient working order and in good repair, with any maintenance log kept up to date. | (legislation.gov.uk, checked 13 November 2026) |
The Health and Safety Executive’s guidance sets out where the regulations stop. Lifts provided for use by workers in workplaces are subject to LOLER, but “in most cases lifting equipment which is not provided for, or used by, people at work (eg stair lifts in private dwellings and platform lifts in shops used for customer access) will not be subject to either LOLER or PUWER”, though businesses providing such equipment remain responsible for its safety, with routine maintenance and inspection (HSE, checked 13 November 2026). Where it is fitted in places with public access, HSE says it is subject to the HSW Act and should be thoroughly examined and inspected using LOLER and PUWER as a guide (HSE, checked 13 November 2026). HSE also notes that “certain slow moving platform lifts (less than 0.15 m/s)” come within the Supply of Machinery (Safety) Regulations instead of the Lift Regulations (HSE, checked 13 November 2026), the regulations volume 2 names for lifting platforms. Upkeep and examinations in practice are on servicing and LOLER.
Who can answer for your building
This page is not legal advice. For a particular building, a building control body can say what the building regulations need, the council’s planning team can say whether permission is needed, and a solicitor or an access consultant can advise on the Equality Act. For a home, an occupational therapist assessing for a council grant looks at what the person needs.
Questions about the rules
For a building other than a home, Approved Document M volume 2 is the government’s guidance on access, and it lists the lifting regulations that are relevant when choosing a lifting device. A business also has the Equality Act’s duty to make reasonable adjustments, and LOLER and PUWER where the lift is used at work. The lift itself is built to a product standard.
GOV.UK says building regulations approval is different from planning permission, that you might need both, and to check with a building control body if you are not sure. Ask one before work starts.
LOLER is about lifting equipment used at work. HSE’s guidance says that in most cases lifting equipment which is not provided for, or used by, people at work, such as stair lifts in private dwellings, will not be subject to either LOLER or PUWER. It does not name step lifts at home.
Read for this page
The pages below are grouped by the day each was last read, newest first. Seen one change? Say which on the contact page, and the corrections page shows what happens next.
- Read on 13 November 2026: BSI Knowledge, BS 6440:2011 (knowledge.bsigroup.com); BSI Knowledge, BS EN 81-40:2020 (knowledge.bsigroup.com); BSI Knowledge, BS EN 81-41:2010 (knowledge.bsigroup.com); BSI Knowledge, BS EN 81-41:2024 - TC (knowledge.bsigroup.com); GOV.UK, Access to and use of buildings: Approved Document M (gov.uk); GOV.UK, Building regulations approval (gov.uk); HM Government, Approved Document M volume 1: dwellings, 2015 edition incorporating 2016 amendments (assets.publishing.service.gov.uk); HM Government, Approved Document M volume 2: buildings other than dwellings, version incorporating 2024 amendments (assets.publishing.service.gov.uk); HSE, LOLER overview, under "Lifting equipment to which LOLER may not apply" (hse.gov.uk); HSE, passenger lifts page, note (hse.gov.uk); legislation.gov.uk, Equality Act 2010, Schedule 2; legislation.gov.uk, Equality Act 2010, section 20; legislation.gov.uk, Equality Act 2010, section 29; legislation.gov.uk, The Lifting Operations and Lifting Equipment Regulations 1998, regulation 2; legislation.gov.uk, The Lifting Operations and Lifting Equipment Regulations 1998, regulation 3; legislation.gov.uk, The Lifting Operations and Lifting Equipment Regulations 1998, regulation 9; legislation.gov.uk, The Provision and Use of Work Equipment Regulations 1998, regulation 5 and Planning Portal, Interactive House mini guide: Accessible adaptations (interactive.planningportal.co.uk).